Packed the tube sheet with dry ice before rolling tubes and the pull numbers came out way tighter
Last month on a 60 inch exchanger at the shop in Beaumont, we were fighting tube leaks on the hydro every single time, maybe 6 out of 40 tubes weeping. One of the older hands told me to pack the tube holes with dry ice about 20 minutes before rolling, said the cold shrinks the tube enough to get a cleaner bite. I figured it was voodoo but we did it, and the next hydro came up dry on the first pass, which almost never happens on that unit. Your mileage may vary depending on wall thickness and what roll you're running, but I'm curious if anyone else has messed with chilling tubes before expanding.